Reversed Femoral & Gama Intramedullary Nail Instrument Set

  • 1200-04

  • CZMEDITECH

  • medical stainless steel

  • CE/ISO:9001/ISO13485

  • FedEx. DHL.TNT.EMS.etc

Availability:
Quantity:

Product Video

PRODUCT OPERATION DETAILS VIDEO

Features & Benefits

Reversed Femoral & Gama Intramedullary Nail Instrument Set

Specification

NO. REF Description Qty.
1 1200-0401 Drill Sleeve 1
2 1200-0402 Drill Sleeve 1
3 1200-0403 Drill Sleeve 1
4 1200-0404 Open Wrench 1
5 1200-0405 Drill Bit Ø4.5 with Stopper 1
6 1200-0406 Drill Bit Ø4.5 1
7 1200-0407 Hex Screwdriver SW3.5 1
8 1200-0408 Depth Gague 0-90mm 1
9 1200-0409 K-wire 2
10 1200-0410 Threaded K-wire 2
11 1200-0411 Drill Bit 1
12 1200-0412 Solid Reamer Ø9 1
13 1200-0413 Solid Reamer Ø10 1
14 1200-0414 Solid Reamer Ø11 1
15 1200-0415 Solid Reamer Ø12 1
16 1200-0416 Solid Reamer Ø13 1
17 1200-0417 AWL 1
18 1200-0418 Wrench 1
19 1200-0419 Quick Coupling T-handle 1
20 1200-0420 Hammer 1
21 1200-0421 T-handle Solid Reamer 1
22 1200-0422 Sleeve 1
23 1200-0423 Sleeve 1
24 1200-0424 Location Forcep 1
25 1200-0425 Sleeve 1
26 1200-0426 Sleeve 1
27 1200-0427 Tap 1
28 1200-0428 Unversal Joint 1
29 1200-0429 Location Forcep 1
30 1200-0430 Guider Bar 1
31 1200-0431 Hex Key Large 1
32 1200-0432 Hex Key Small 1
33 1200-0433 Forcing Cone Short 1
34 1200-0434 Forcing Cone Long 1
35 1200-0435 Connector 1
36 1200-0436 Connector 1
37 1200-0437 Guider Handle 1
38 1200-0438 Bolt 1
39 1200-0439 Bolt 1
40 1200-0440 Guider Wire 1
41 1200-0441 Aluminium Box 1


Actual Picture

Reversed Femoral & Gama Intramedullary Nail Instrument Set

Blog

Reversed Femoral & Gamma Intramedullary Nail Instrument Set: A Comprehensive Guide

When it comes to treating fractures of the femur, intramedullary nailing has become a popular technique among orthopedic surgeons. Among the various types of intramedullary nails, reversed femoral and gamma intramedullary nails have gained significant attention due to their numerous advantages. In this article, we will explore what these nails are, their benefits, the instrument set required for the surgery, and other relevant details.

Table of Contents

  • Introduction

  • Anatomy of the Femur Bone

  • What is an Intramedullary Nail?

  • Reversed Femoral and Gamma Intramedullary Nails: What Are They?

  • Benefits of Reversed Femoral and Gamma Intramedullary Nails

  • Indications for Reversed Femoral and Gamma Intramedullary Nails

  • Contraindications for Reversed Femoral and Gamma Intramedullary Nails

  • Surgical Technique for Reversed Femoral and Gamma Intramedullary Nails

  • Instrument Set Required for Reversed Femoral and Gamma Intramedullary Nailing

  • Postoperative Care and Rehabilitation

  • Potential Complications of Reversed Femoral and Gamma Intramedullary Nailing

  • Conclusion

  • FAQs

Introduction

Fractures of the femur can be challenging to treat due to the bone's large size and complex anatomy. The use of intramedullary nails has become increasingly popular among orthopedic surgeons due to their numerous benefits over other forms of treatment. In this article, we will explore the use of reversed femoral and gamma intramedullary nails, their benefits, the surgical technique required, the instrument set needed, and potential complications.

Anatomy of the Femur Bone

Before delving into intramedullary nailing, it is essential to understand the anatomy of the femur bone. The femur is the longest and strongest bone in the human body, extending from the hip joint to the knee joint. The proximal end of the femur articulates with the hip bone, while the distal end articulates with the tibia bone of the leg.

What is an Intramedullary Nail?

An intramedullary nail is a long, slender metal rod inserted into the hollow part of a bone called the medullary canal. The rod is typically made of titanium or stainless steel and is designed to stabilize the bone during the healing process. Intramedullary nailing is commonly used for fractures of the long bones, such as the femur and tibia.

Reversed Femoral and Gamma Intramedullary Nails: What Are They?

Reversed femoral and gamma intramedullary nails are types of intramedullary nails used for fractures of the femur. Reversed femoral nails are designed to be inserted into the femur from the distal end of the bone, opposite to the direction of insertion of a traditional intramedullary nail. Gamma nails, on the other hand, are inserted from the proximal end of the femur and are designed to curve within the bone.

Benefits of Reversed Femoral and Gamma Intramedullary Nails

The use of reversed femoral and gamma intramedullary nails offers several benefits over traditional intramedullary nailing techniques. These benefits include:

  • Reduced surgical time and blood loss

  • Smaller incisions

  • Less damage to the soft tissues surrounding the fracture

  • Earlier weight-bearing and return to function

  • Better alignment of the fracture

Indications for Reversed Femoral and Gamma Intramedullary Nails

Reversed femoral and gamma intramedullary nails are commonly used for fractures of the femur in patients of all ages, including adults and children. They are particularly useful for treating fractures that are located in the middle of the femur shaft or those that extend into the femur's proximal or distal regions.

Contraindications for Reversed Femoral and Gamma Intramedullary Nails

While reversed femoral and gamma intramedullary nailing offer several benefits, they are not suitable for all patients. Contraindications for these procedures include:

  • Fractures located near the hip joint or knee joint

  • Severe osteoporosis or other bone disorders that compromise the bone's strength

  • Inability to tolerate the surgery due to underlying medical conditions

Surgical Technique for Reversed Femoral and Gamma Intramedullary Nails

The surgical technique for reversed femoral and gamma intramedullary nailing involves several steps. First, the patient is placed under general anesthesia, and the fracture is visualized using fluoroscopy or other imaging techniques. Next, a small incision is made at the distal or proximal end of the femur, depending on the type of nail being used. The nail is then inserted into the medullary canal and guided into place using specialized instruments. Once the nail is in the correct position, locking screws are inserted to secure the nail to the bone.

Instrument Set Required for Reversed Femoral and Gamma Intramedullary Nailing

Performing reversed femoral and gamma intramedullary nailing requires a specialized instrument set. The set typically includes:

  • Intramedullary reamers

  • Nail insertion and targeting devices

  • Guide wires and locking screws

  • Instruments for preparing the bone and soft tissues surrounding the fracture

Postoperative Care and Rehabilitation

Following surgery, patients typically require several days of hospitalization. The leg is immobilized using a cast or brace, and pain medications are prescribed as needed. Patients are usually advised to avoid putting weight on the affected leg for several weeks to allow for proper healing. Physical therapy may be recommended to help regain strength and range of motion in the affected leg.

Potential Complications of Reversed Femoral and Gamma Intramedullary Nailing

As with any surgical procedure, reversed femoral and gamma intramedullary nailing can carry certain risks and complications. These may include:

  • Infection

  • Blood clots

  • Nerve or blood vessel damage

  • Implant failure or migration

  • Delayed or non-union of the fracture

Conclusion

Reversed femoral and gamma intramedullary nailing have emerged as popular options for treating fractures of the femur. These techniques offer several advantages over traditional intramedullary nailing, including reduced surgical time, smaller incisions, and faster recovery times. However, they are not suitable for all patients and carry certain risks and complications. Careful patient selection and surgical technique are critical to achieving optimal outcomes.

FAQs

  1. How long does it take to recover from reversed femoral or gamma intramedullary nailing?

  • Recovery times can vary depending on the severity of the fracture and the patient's overall health. In general, most patients can expect to be off their feet for several weeks and may require several months of physical therapy to regain full strength and range of motion.

  1. Is reversed femoral or gamma intramedullary nailing painful?

  • Patients may experience some pain and discomfort following the surgery, which can be managed with pain medications prescribed by the doctor.

  1. Can anyone undergo reversed femoral or gamma intramedullary nailing?

  • No, these techniques are not suitable for all patients. Your doctor will evaluate your condition and medical history to determine if you are a good candidate for these procedures.

  1. How long does the surgery take?

  • The surgery typically takes between 1-2 hours, but this can vary depending on the complexity of the fracture and the patient's individual anatomy.

  1. Are there any alternative treatments to reversed femoral or gamma intramedullary nailing?

  • Yes, there are several alternative treatments for femoral fractures, including external fixation, traditional intramedullary nailing, and open reduction and internal fixation. Your doctor will recommend the best treatment approach based on your individual needs and condition.


Previous: 
Next: 

Consult Your CZMEDITECH Orthopedic Experts

We help you avoid the pitfalls to delivery the quality and value your orthopedic need, on-time and on-budget.
Changzhou Meditech Technology Co., Ltd.

Products

  FIME   
  June 19-21, 2024  
Miami Beach Convention Center
Miami Beach, USA
Booth No.: X75

Service

Inquiry Now
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.