Have any questions?       +86-18112515727       song@orthopedic-china.com
You are here: Home » Products » Non-locking Plate » Large Fragment » Tibial Platform Lateral Plate-II

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Tibial Platform Lateral Plate-II

  • 4100-42

  • CZMEDITECH

  • Stainless Steel / Titanium

  • CE/ISO:9001/ISO13485

  • FedEx. DHL.TNT.EMS.etc

Availability:
Quantity:

Product Description

CZMEDITECH Tibial Platform Lateral Plate-II

Introduction

Tibial Platform Lateral Plate manufactured by CZMEDITECH for treatment of fractures can be used for trauma repair and reconstruction of Tibial.


This series of orthopaedic implant has passed ISO 13485 certification, qualified for CE mark and a variety of specifications which are suitable for Tibial fractures. They are easy to operate, comfortable and stable during use.


With Czmeditech's new material and improved manufacturing technology, our orthopaedic implants have exceptional properties. It is lighter and stronger with high tenacity. Plus, it is less likely to set off an allergic reaction.


For more detailed information on our products, please contact us at your earliest convenience.





Features & Benefits

胫骨平台外侧钢板-II

Specification

Specification
5/6/7/8/9/10/11 holes
L/R
Brand
CZMEDITECH
Material
Stainless steel/Titanium alloy
Certificate
CE,ISO13485
Other
Customizable
Delivery Way
DHL/UPS/FEDEX/TNT/ARAMAX/EMS
Delivery Time
3-7 days

Actual Picture

Tibial Platform Lateral Plate

Popular Science Content

Tibial Platform Lateral Plate: An Overview of Its Usage, Advantages, and Disadvantages

When it comes to orthopedic surgeries, one of the most important aspects is the fixation of fractures. Tibial plateau fractures are common among individuals, and require an effective method of fixation. The tibial platform lateral plate is a recent innovation in the field of orthopedic surgery, and has proven to be an effective method of fixation. In this article, we will delve into the usage, advantages, and disadvantages of the tibial platform lateral plate.

What is a Tibial Platform Lateral Plate?

A tibial platform lateral plate is an implant used to fixate fractures of the tibial plateau. The tibial plateau is the upper part of the tibia bone that articulates with the femur bone of the thigh. The tibial platform lateral plate is made of stainless steel, titanium, or a combination of both. It is designed to be placed on the lateral aspect of the tibial plateau to provide stable fixation of the fracture.

Indications for Tibial Platform Lateral Plate

The tibial platform lateral plate is primarily used for the treatment of fractures of the tibial plateau. These fractures may result from high-energy injuries, such as car accidents or falls from a height. They may also occur in individuals with weakened bones, such as those with osteoporosis. The use of a tibial platform lateral plate is indicated when the fracture involves the lateral aspect of the tibial plateau and when the fracture is displaced or comminuted.

Advantages of Tibial Platform Lateral Plate

The tibial platform lateral plate has several advantages over other methods of fixation. One of the main advantages is that it provides stable fixation of the fracture, which allows for early mobilization of the joint. This can lead to faster recovery times and a quicker return to normal activities. Additionally, the use of the tibial platform lateral plate allows for anatomical reduction of the fracture, which can lead to improved joint function and a reduced risk of post-traumatic arthritis. The implant is also relatively easy to insert and has a low complication rate.

Disadvantages of Tibial Platform Lateral Plate

While the tibial platform lateral plate has many advantages, there are also some potential disadvantages. One of the main disadvantages is that it is an invasive procedure that requires a surgical incision. This can lead to increased pain, risk of infection, and prolonged recovery times. Additionally, the implant may need to be removed in some cases due to irritation or discomfort. There is also a risk of hardware failure, which can lead to a need for revision surgery.

Surgical Technique for Tibial Platform Lateral Plate

The surgical technique for inserting a tibial platform lateral plate involves making an incision on the lateral aspect of the knee. The fracture is then reduced and the plate is fixed to the bone using screws. The number and placement of screws will depend on the size and location of the fracture. After the plate is fixed to the bone, the incision is closed and the patient is immobilized using a brace or cast. Rehabilitation will typically involve physical therapy and weight-bearing exercises.

Complications of Tibial Platform Lateral Plate

While the tibial platform lateral plate has a low complication rate, there are still some potential complications that can occur. One of the main complications is infection, which can occur at the site of the surgical incision. Other complications may include implant failure, nonunion of the fracture, and malalignment of the joint. Patients may also experience pain, swelling, and stiffness in the affected joint.

Recovery and Rehabilitation After Tibial Platform Lateral Plate

Recovery and rehabilitation after a tibial platform lateral plate surgery can vary depending on the extent of the fracture and the patient's individual circumstances. Generally, patients will be immobilized using a brace or cast for several weeks after surgery to allow for proper healing of the fracture. After the immobilization period, physical therapy will be initiated to help regain range of motion, strength, and function of the affected joint. This may involve exercises such as walking, cycling, and swimming, as well as targeted stretching and strengthening exercises.

Follow-Up Care and Monitoring

Patients who have undergone tibial platform lateral plate surgery will require regular follow-up appointments with their healthcare provider to monitor their progress and ensure proper healing of the fracture. This may involve imaging tests such as X-rays or CT scans to assess the bone healing and alignment of the joint. Patients should also report any new or worsening symptoms, such as pain, swelling, or stiffness, to their healthcare provider promptly.

Conclusion

The tibial platform lateral plate is an effective method of fixation for fractures of the tibial plateau. While there are potential risks and complications associated with the surgery, the advantages of stable fixation and anatomical reduction of the fracture make it a valuable treatment option. Patients should discuss the risks and benefits of tibial platform lateral plate surgery with their healthcare provider to determine the best course of treatment for their individual circumstances.

FAQs

  1. Is tibial platform lateral plate surgery painful?

Patients may experience pain after tibial platform lateral plate surgery, but this can typically be managed with pain medication and proper post-operative care.

  1. How long does it take to recover from tibial platform lateral plate surgery?

Recovery time can vary depending on the extent of the fracture and the patient's individual circumstances. Generally, patients will require several weeks of immobilization followed by physical therapy to regain range of motion and strength.

  1. Can a tibial platform lateral plate be removed?

In some cases, a tibial platform lateral plate may need to be removed due to irritation or discomfort. This can typically be done as a separate procedure after the fracture has healed.

  1. Are there any alternatives to tibial platform lateral plate surgery?

Other methods of fixation for tibial plateau fractures include external fixation, percutaneous screws, and locking plates. The best treatment option will depend on the extent of the fracture and the patient's individual circumstances.

  1. What is the success rate of tibial platform lateral plate surgery?

The success rate of tibial platform lateral plate surgery is generally high, with good outcomes in most patients. However, individual outcomes may vary depending on factors such as the extent of the fracture and the patient's overall health.


Tibial Platform Lateral Plate

  1. Material sensitivity documented or suspected.

  2. Infection, osteoporosis or other diseases hindering healing up of bone.

  3. Compromised vascularity that would inhibit adequate blood supply to the fracture or the operative site.

  4. Patients having inadequate tissue coverage over the operative sit.

  5. Abnormity of bone structure.

  6. Local infection happens at operation area and local inflammation symptom appears.

  7. Children.

  8. Overweight.:An overweight or obese patient can produce loads on the plate which can lead to failure of the fixation of the device or to failure of the device itself.

  9. Mental illness.

  10. Patients unwilling to cooperate in after treatment.

  11. Other medical or surgical condition which would preclude the potential benefit of surgery.

  12. Patients having any other surgery contraindication.

Fited screw:

φ4.5mm cortical screw, 6.5mm cancellous screw

All plate are available in stainless steel or titanium

All screws are available in stainless steel or titanium

Features & Benefits

*Easy to bend, with lower notch

*Anatomical design,accommodate with the bone shape

*Can be shaping during surgery

Why choose CZMEDITECH Small Fragment system:

*Made of high quality pure titanium and first-rate equipment

*Advanced surface oxidation process ensure decent appearance and great resistance

*Little soft tissue irritation thanks to low-profile design, smooth surface and round edge

*Matching screws and other all instruments are available

*Valid official proof certification.such as CE, ISO13485

*Very competitive price and very quick delivery








Previous: 
Next: 

Consult Your CZMEDITECH Orthopedic Experts

We help you avoid the pitfalls to delivery the quality and value your orthopedic need, on-time and on-budget.
Changzhou Meditech Technology Co., Ltd.

Products

  FIME   
  June 19-21, 2024  
Miami Beach Convention Center
Miami Beach, USA
Booth No.: X75

Service

Inquiry Now
© COPYRIGHT 2023 CHANGZHOU MEDITECH TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.